Features
SS151 series piezoresistive pressure transducers are mainly used for measuring hydrogen gas. Gold plating on stainless steel prevents hydrogen gas from entering. This prevents brittleness and maintains the metal’s toughness. The transducers’ pressure ranges from 35 KPa to 60 MPa.
Several million of these pressure transducers are in use worldwide across various applications.
Main fields of application include:
- Process control systems
- Hydraulic systems and valves
- Hydrogen measurement
- Hydrogen vehicles
Pressure ranges (typical)
Vented gauge (defining atmospheric pressure as zero) (Unit: bar)
| Range | -1.0 | -0.7 | -0.35 | 0.35 | 0.7 | 1.0 |
|---|---|---|---|---|---|---|
| 2.5 | 4.0 | 6.0 | 10 | 16 | 25 | |
Vented gauge (defining atmospheric pressure as zero) (Unit: bar)
| Range | 1.0 | 2.5 | 4.0 | 6.0 | 10 | 16 |
|---|---|---|---|---|---|---|
| 25 | 40 | 60 | 100 | 160 | 250 | |
| 400 | 600 |
Sealed gauge (defining standard atmospheric pressure as zero) (Unit: bar)
| Range | 10 | 16 | 25 | 40 | 60 | 100 |
|---|---|---|---|---|---|---|
| 160 | 250 | 400 | 600 |
Technical data
Performance (EN 60770)
| Power supply | 1.5 mADC (typical) | 5 VDC (optional) | 10 VDC (optional) |
|---|---|---|---|
| Zero output | 0 ± 2 mV ① | ||
| Span output | 100 ± 20 mV ① | ||
| Accuracy | 0.25% F.S. ① | ||
| Overload range | 2.0 × F.S. (≤ 250 bar) | ||
| 1.5 × F.S. (> 250 bar) | |||
| Compensated temp range | 0 → 70 °C | ||
| Operating temp range | -20 → 100 °C | ||
| Storage temp range | -40 → 125 °C | ||
| Zero thermal error | ≤ 0.02% F.S./°C | ||
| Sensitivity thermal error | ≤ 0.02% F.S./°C | ||
| Stability | ≤ 0.2% F.S./Year | ||
| Input impedance | 2.3 → 4 KΩ | ||
| Insulation resistance | > 100 MΩ at 250 V | ||
| Vibration | 20g / (20 to 5000 Hz) | ||
| Endurance | > 100 x 106 F.S. cycles | ||
①: The zero output, span output and accuracy may different if the supply power, measuring range and pressure type is different, please contact us if you need more details.
Mechanical characteristics
| Power supply | 1.5 mADC (typical) | 5 VDC (optional) | 10 VDC (optional) |
|---|---|---|---|
| Zero output | 0 ± 2 mV ① | ||
| Span output | 100 ± 20 mV ① | ||
| Accuracy | 0.25% F.S. ① | ||
| Overload range | 2.0 × F.S. (≤ 250 bar) | ||
| 1.5 × F.S. (> 250 bar) | |||
| Compensated temp range | 0 → 70 °C | ||
| Operating temp range | -20 → 100 °C | ||
| Storage temp range | -40 → 125 °C | ||
| Zero thermal error | ≤ 0.02% F.S./°C | ||
| Sensitivity thermal error | ≤ 0.02% F.S./°C | ||
| Stability | ≤ 0.2% F.S./Year | ||
| Input impedance | 2.3 → 4 KΩ | ||
| Insulation resistance | > 100 MΩ at 250 V | ||
| Vibration | 20g / (20 to 5000 Hz) | ||
| Endurance | > 100 x 106 F.S. cycles | ||
Electrical connections
| wires | 4-Pins / 5-Pins connection mode | ||||
|---|---|---|---|---|---|
| Color | Function | # |
PIN1: Supply + | ||
| Red | Supply + | PIN2: Output – | |||
| Black | Supply – | PIN3: Supply – | |||
| White | Output + | PIN4: Supply – ② | |||
| Blue | Output – | PIN5: Output + | |||
②: PIN4 is not used for 4-Pins connection